All about glass > Acoustic insulation index : R
Europe's most precise sound reduction index for glass is Ratr ( Ratr= Rw+Ctr) often called R and expressed in decibels (dB). We will use this index to state glass acoustic performance. For further information, please contact us.Some single glazings acoustic values :
4 mm | 6 mm |
8 mm ou Plastofloat 68 (33/2) |
10 mm |
12 mm ou Plastofloat 128 (66/2) |
Plastofloat acoustique 88 (44/2) |
19 mm |
Plastofloat acoustique 128 (66/2) |
|
R | 26* | 28* | 29* | 30* | 32* | 33,9** | 34*** | 37** |
*according to EN 12 758
**Test results, experimental values obtained by our samples, measured according to NF EN ISO 140 specifications
*** calculated values, values calculated simulating the NF EN 140 conditions